Harmonization: Automated Calibration Curves & Multi-Instrument Alignment

📋 Standard Header

Purpose: Align spectra from multiple instruments to enable cross-instrument model transfer and harmonized datasets.

When to Use: - Combine spectral data from different instruments into one unified dataset - Transfer trained model from reference instrument to new instruments - Correct for wavenumber shifts between instruments - Normalize intensity differences due to laser power or detector sensitivity - Build multi-site collaborative datasets with instrument harmonization

Inputs: - Format: Multiple HDF5 files (one per instrument) with overlapping samples - Required metadata: instrument_id (unique identifier per instrument) - Optional metadata: laser_power_mw, integration_time_ms (for intensity normalization) - Wavenumber range: Overlapping range across all instruments (typically 600–1800 cm⁻¹) - Min samples: 20+ shared samples per instrument pair for calibration curve estimation

Outputs: - calibration_curves.pkl — Wavenumber shift corrections for each instrument - harmonized_datasets/ — Aligned HDF5 files on common wavenumber grid - diagnostics.csv — Shift (cm⁻¹), correlation, RMSE for each instrument pair - alignment_plot.png — Spectra before/after alignment for visual verification - report.md — Summary of harmonization quality and recommended corrections

Assumptions: - Instruments measure same samples (overlapping subset required for calibration) - Wavenumber shifts are linear and consistent (global offset, not sample-dependent) - Intensity differences due to instrument factors, not chemical differences - Reference instrument spectra are high-quality baseline for alignment


🔬 Minimal Reproducible Example (MRE)

import numpy as np
import matplotlib.pyplot as plt
from foodspec import SpectralDataset
from foodspec.harmonization import estimate_calibration_curve, harmonize_datasets_advanced
from foodspec.viz.harmonization import plot_harmonization_comparison

# Generate synthetic multi-instrument data
def generate_synthetic_multi_instrument(n_samples=50, shift_cm=3.0, intensity_scale=1.2, random_state=42):
    """Create reference and target instrument datasets with known shift."""
    np.random.seed(random_state)
    wavenumbers_ref = np.linspace(600, 1800, 400)
    wavenumbers_target = wavenumbers_ref + shift_cm  # Simulated wavenumber shift

    spectra_ref = []
    spectra_target = []

    for i in range(n_samples):
        # Base spectrum
        spectrum = 1.5 * np.exp(-((wavenumbers_ref - 1655) ** 2) / 2000) + \
                   1.2 * np.exp(-((wavenumbers_ref - 1450) ** 2) / 1500) + \
                   np.random.normal(0, 0.05, len(wavenumbers_ref))

        spectra_ref.append(spectrum)

        # Target spectrum (shifted + intensity scaled)
        spectrum_target = intensity_scale * spectrum + np.random.normal(0, 0.03, len(wavenumbers_ref))
        spectra_target.append(spectrum_target)

    import pandas as pd

    # Create reference dataset
    df_ref = pd.DataFrame(
        np.array(spectra_ref),
        columns=[f"{w:.1f}" for w in wavenumbers_ref]
    )
    df_ref.insert(0, 'sample_id', [f"S{i:03d}" for i in range(n_samples)])
    df_ref.insert(1, 'instrument_id', 'InstrumentA')

    fs_ref = SpectralDataset.from_dataframe(
        df_ref,
        metadata_columns=['sample_id', 'instrument_id'],
        intensity_columns=[f"{w:.1f}" for w in wavenumbers_ref],
        wavenumber=wavenumbers_ref
    )

    # Create target dataset (with shift)
    df_target = pd.DataFrame(
        np.array(spectra_target),
        columns=[f"{w:.1f}" for w in wavenumbers_target]
    )
    df_target.insert(0, 'sample_id', [f"S{i:03d}" for i in range(n_samples)])
    df_target.insert(1, 'instrument_id', 'InstrumentB')

    # Interpolate to common grid for SpectralDataset
    spectra_target_interp = []
    for spectrum in spectra_target:
        spectrum_interp = np.interp(wavenumbers_ref, wavenumbers_target, spectrum)
        spectra_target_interp.append(spectrum_interp)

    df_target_interp = pd.DataFrame(
        np.array(spectra_target_interp),
        columns=[f"{w:.1f}" for w in wavenumbers_ref]
    )
    df_target_interp.insert(0, 'sample_id', [f"S{i:03d}" for i in range(n_samples)])
    df_target_interp.insert(1, 'instrument_id', 'InstrumentB')

    fs_target = SpectralDataset.from_dataframe(
        df_target_interp,
        metadata_columns=['sample_id', 'instrument_id'],
        intensity_columns=[f"{w:.1f}" for w in wavenumbers_ref],
        wavenumber=wavenumbers_ref
    )

    return fs_ref, fs_target, shift_cm, intensity_scale

# Generate data
fs_ref, fs_target, true_shift, true_scale = generate_synthetic_multi_instrument(
    n_samples=50,
    shift_cm=3.0,
    intensity_scale=1.2
)
print(f"Reference instrument: {fs_ref.metadata['instrument_id'].iloc[0]}")
print(f"Target instrument: {fs_target.metadata['instrument_id'].iloc[0]}")
print(f"True wavenumber shift: {true_shift:.1f} cm⁻¹")
print(f"True intensity scale: {true_scale:.2f}")

# Estimate calibration curve
curve, diagnostics = estimate_calibration_curve(fs_ref, fs_target)
print(f"\nEstimated shift: {diagnostics['shift_cm']:.2f} cm⁻¹")
print(f"Correlation: {diagnostics['corr_coeff']:.4f}")
print(f"RMSE: {diagnostics['rmse']:.4f}")

# Harmonize datasets
harmonized = harmonize_datasets_advanced(
    [fs_ref, fs_target],
    calibration_curves={'InstrumentB': curve},
    intensity_meta_key=None  # or 'laser_power_mw' if available
)

print(f"\nHarmonization complete:")
for inst_id, ds in harmonized.items():
    print(f"  {inst_id}: {ds.x.shape[0]} spectra on common grid")

# Plot before/after comparison
fig, axes = plt.subplots(1, 2, figsize=(14, 5))

# Before harmonization
axes[0].plot(fs_ref.wavenumber, fs_ref.x[0], label='Reference', alpha=0.7)
axes[0].plot(fs_target.wavenumber, fs_target.x[0], label='Target (before)', alpha=0.7)
axes[0].set_xlabel('Wavenumber (cm⁻¹)')
axes[0].set_ylabel('Intensity')
axes[0].set_title('Before Harmonization')
axes[0].legend()
axes[0].grid(alpha=0.3)

# After harmonization
axes[1].plot(harmonized['InstrumentA'].wavenumber, harmonized['InstrumentA'].x[0], label='Reference', alpha=0.7)
axes[1].plot(harmonized['InstrumentB'].wavenumber, harmonized['InstrumentB'].x[0], label='Target (after)', alpha=0.7)
axes[1].set_xlabel('Wavenumber (cm⁻¹)')
axes[1].set_ylabel('Intensity')
axes[1].set_title('After Harmonization')
axes[1].legend()
axes[1].grid(alpha=0.3)

plt.tight_layout()
plt.savefig("harmonization_comparison.png", dpi=150, bbox_inches='tight')
print("Saved: harmonization_comparison.png")

Expected Output:

Reference instrument: InstrumentA
Target instrument: InstrumentB
True wavenumber shift: 3.0 cm⁻¹
True intensity scale: 1.20

Estimated shift: 2.98 cm⁻¹
Correlation: 0.9856
RMSE: 0.0234

Harmonization complete:
  InstrumentA: 50 spectra on common grid
  InstrumentB: 50 spectra on common grid

Saved: harmonization_comparison.png


✅ Validation & Sanity Checks

Success Indicators

Diagnostics: - ✅ Estimated shift close to known/expected shift (if calibration standard used) - ✅ Correlation > 0.95 between reference and aligned target - ✅ RMSE < 0.05 (normalized intensity units)

Visual Comparison: - ✅ Before: Spectra misaligned (peaks shifted) - ✅ After: Spectra overlapping (peaks aligned) - ✅ Peak positions match across instruments

Model Transfer: - ✅ Model trained on reference instrument performs well on harmonized target data - ✅ Cross-instrument CV accuracy similar to within-instrument CV

Failure Indicators

⚠️ Warning Signs:

  1. Correlation < 0.85 after harmonization
  2. Problem: Non-linear shifts; different spectral features; sample mismatch
  3. Fix: Verify same samples measured; check for different baseline/normalization; use more calibration samples

  4. Estimated shift > 10 cm⁻¹

  5. Problem: Instruments very poorly calibrated; using different spectral ranges
  6. Fix: Recalibrate instruments; verify wavenumber axes correct; check if Raman vs FTIR

  7. Harmonized spectra still visually misaligned

  8. Problem: Linear shift insufficient; baseline differences; matrix effects
  9. Fix: Apply baseline correction before harmonization; use piecewise linear or polynomial calibration curves

  10. Model transfer accuracy drops > 20% on harmonized data

  11. Problem: Intensity normalization inadequate; features not transferable; batch effects
  12. Fix: Include intensity metadata (laser power); use robust features (ratios); train on multi-instrument data

Quality Thresholds

Metric Minimum Good Excellent
Correlation (after) 0.85 0.95 0.99
RMSE (normalized) < 0.10 < 0.05 < 0.02
Shift Estimation Error < 2 cm⁻¹ < 1 cm⁻¹ < 0.5 cm⁻¹
Model Transfer Accuracy Drop < 20% < 10% < 5%

⚙️ Parameters You Must Justify

Critical Parameters

1. Reference Instrument - Parameter: reference_instrument_id - No default: Must specify - Justification: "InstrumentA chosen as reference due to highest SNR and largest calibration dataset."

2. Max Shift Search Range - Parameter: max_shift_points (search window for wavenumber shift) - Default: 25 points (~6 cm⁻¹ at 0.25 cm⁻¹ resolution) - When to adjust: Increase (50) if instruments very misaligned; decrease (10) if well-calibrated - Justification: "Max shift of ±6 cm⁻¹ searched to accommodate typical Raman calibration drift."

3. Intensity Normalization Key - Parameter: intensity_meta_key (metadata column for intensity correction) - Default: None (no intensity normalization) - When to adjust: Use 'laser_power_mw' if available and variable across instruments - Justification: "Intensity normalized by laser power (metadata: laser_power_mw) to correct for instrument-specific detector sensitivity."

4. Common Wavenumber Grid - Parameter: Interpolation target grid (start, stop, resolution) - Default: Intersection of all instrument ranges at finest resolution - Justification: "All spectra interpolated to common 600–1800 cm⁻¹ grid at 1 cm⁻¹ resolution for harmonization."


Calibration Curve Estimation

Automated Curve Generation

For instruments without pre-computed calibration curves, use automatic curve estimation:

from foodspec import SpectralDataset
from foodspec.harmonization import estimate_calibration_curve, generate_calibration_curves

# Load reference and target instrument datasets
reference_ds = SpectralDataset.from_hdf5("reference_instrument.h5")
target_ds = SpectralDataset.from_hdf5("target_instrument.h5")

# Estimate one curve (reference → target)
curve, diagnostics = estimate_calibration_curve(reference_ds, target_ds)
print(f"Shift: {diagnostics['shift_cm']} cm^-1")
print(f"Correlation: {diagnostics['corr_coeff']:.4f}")

Bulk Calibration Curve Generation

For multiple instruments, generate curves relative to a reference instrument:

from pathlib import Path

# Load all datasets
datasets = [
    SpectralDataset.from_hdf5(f)
    for f in Path("data").glob("*.h5")
]

# Generate curves for all vs. reference instrument
curves, diagnostics = generate_calibration_curves(
    datasets,
    reference_instrument_id="InstrumentA",
    max_shift_points=25  # search range
)

for inst_id, curve in curves.items():
    print(f"{inst_id}: shift = {diagnostics[inst_id]['shift_cm']:.2f} cm^-1")

Multi-Instrument Harmonization Workflow

Full Harmonization Pipeline

from foodspec.harmonization import harmonize_datasets_advanced

# Apply calibration curves + intensity normalization + common grid alignment
harmonized_datasets, diag = harmonize_datasets_advanced(
    datasets,
    calibration_curves=curves,
    intensity_meta_key="laser_power_mw"  # or None if not available
)

print(f"Target grid length: {len(harmonized_datasets[0].wavenumbers)}")
print(f"Residual variation: {diag['residual_std_mean']:.4f}")

Intensity Normalization

Correct for laser power variations:

from foodspec.harmonization import intensity_normalize_by_power

for ds in datasets:
    power_mw = ds.instrument_meta.get("laser_power_mw")
    ds_norm = intensity_normalize_by_power(ds, power_mw)

Mathematical Assumptions

  1. Calibration Curve Linearity: Wavenumber drift is modeled as a linear shift (suitable for stable instruments).
  2. Paired Standards: The reference and target instruments measure the same standard samples (required for curve fitting).
  3. Intensity Additivity: Laser power affects intensity multiplicatively: $I_{\text{corrected}} = I_{\text{observed}} / P_{\text{mW}}$.
  4. Common Grid Alignment: Spectra are interpolated to a shared wavenumber grid (assumes smooth spectral features).

Failure Modes & Diagnostics

Poor Correlation During Curve Estimation

Symptom: Low corr_coeff (< 0.8) in diagnostics.
Cause: Spectra too different, or instruments not measuring the same samples.
Solution: Inspect the raw spectra; ensure standards are authentic and representative.

Residual Variation High

Symptom: residual_std_mean > expected noise level.
Cause: Incomplete harmonization; possible instrument drift or scale mismatch.
Solution: Increase max_shift_points range; verify intensity metadata.

Misaligned Peaks Post-Harmonization

Symptom: Peaks don't align after harmonization.
Cause: Nonlinear wavenumber drift not captured by linear model.
Solution: Use manual calibration points or export all data to vendor software for advanced correction.

Advanced: Manual Calibration Curves

If automated estimation fails, create curves manually:

from foodspec.harmonization import CalibrationCurve

# Define manually (e.g., from vendor calibration)
curve = CalibrationCurve(
    instrument_id="InstrumentB",
    wn_source=np.array([1000, 1100, 1200, ...]),  # expected wavenumbers
    wn_target=np.array([1001, 1102, 1199, ...])   # observed wavenumbers
)

# Apply to dataset
ds_corrected = apply_calibration(ds, curve)

Outputs & Reproducibility

All harmonization operations are logged in SpectralDataset.logs and SpectralDataset.history:

print("\n".join(harmonized_datasets[0].logs))
# Output:
# harmonized_to_grid len=3601
# advanced_harmonized_to_grid len=3601
# ...

print(harmonized_datasets[0].history)
# [{'step': 'advanced_harmonize', 'len_grid': 3601}, ...]

See Also